Service Instructions
Page 93
Service Manual Deli Multisserie form 9123560 rev. 09/2017
Exchanging plastic gutters, complete with
curved panels.
1. Remove the 4 plastic finishing plugs.
It
is almost impossible to get them out in
one piece. Therefore, the easiest way is to
carefully tick them inwards with a slotted
screwdriver as shown on the picture.
2. Unscrew the 4 screws (M5x45) behind the
finishing plugs.
3. Take out the complete panel/gutter as-
sembly.
4. Unscrew the M5x12 screws for reuse, and
dispose the gutters and panels according
local legislations.
5. Mount the new panel with the M5x45
screws with help of the nylon spacers.
6. Mount the gutter with the M5x12 screws.
If necessary, pull the drainhose on the
gutter outlet with snipe nose pliers.
7. Finish the holes with the finishing plugs.
8. Repeat this for all 3 doors.
Related parts that can be reused.
12x 4288232 Screw M5x12
12x 4280218 Screw M5x45
12x 9057347 Spacer 10mm, nylon
ø5xø10mm
In case it is preferred to mount the gutters on new adapted curved panels, these can be ordered
with the part numbers, mentioned below. Note that the middle door has no grids in the curved
panel and has therefore a different part number.
12x 2005250 Finishing plug
1x 9194866s Curved panel
2x 9194865s Curved panel
3x 9192275 Stainless gutter