Spread Spectrum Wireless Data Transceiver User Manual
4.
The system will automatically prompt for Repeater 1’s number. If no Repeaters are being used,
press the
Esc
key. Otherwise, enter the 7-digit serial number of the Repeater.
5.
The system will then prompt for Repeater 2’s number. Enter the 7-digit serial number of the
second Repeater. If only one Repeater is being used, press the
Esc
key.
6.
The system refreshes the transceiver’s Call Book menu with any changes.
7.
Press the
Esc
key to return to the transceiver’s Main Menu.
P
ROGRAMMING
P
OINT
-
TO
-P
OINT
E
XTENDED
C
ALL
B
OOK TO
U
SE
T
HREE OR
F
OUR
R
EPEATERS
In a Point-to-Point link FreeWave transceivers can utilize up to 4 Repeaters. To use 3 or 4 Repeaters,
program the Call Book with the Slave being called, followed by the first 2 Repeaters being used from the
perspective of the Master calling out to the Slave. On the next Call Book line enter 999-9999 as the next
transceiver to call. When prompted for the Repeaters enter the third and fourth Repeaters in the link.
The illustration below depicts a Point-to-Point link where a Slave is called through 4 Repeaters. In this
example the Master is calling the Slave, 571-3872, through Repeater 1, 901-1234, then Repeater 2, 910-
0234, then Repeater 3, 571-3456, and finally Repeater 4, 571-4567. Note that it is the entry of serial
number 999-9999 in line 1 that instructs the Master to continue calling through the Repeaters
programmed on that line.
It is important that the Call Book slots (0-9) are filled sequentially starting with slot 0. Serial numbers do
not need to be entered in numerical order, however. When a Master is instructed to Call All, it will call all
Slaves listed until it reaches the first serial number of 000-0000. If a valid serial number is entered after
the all zero number or as a Repeater, it will not be recognized as a valid number to call by the Master.
LUM0002AD Version
6.1