FR500F Series Special Purpose Inverter
- 25 -
F08.09
Rotor resistance R2 of
async motor 1
0.001
~
65.535Ω
Model
defined
×
F08.10
Leakage inductance L1
of async motor 1
0.01
~
655.35mH
Model
defined
×
F08.11
Mutual inductance L2 of
asynchronous motor 1
0.1
~
6553.5mH
Model
defined
×
F08.12
No-load current of
async motor 1
0.1
~
1500.0A
Model
defined
×
F08.13
Field weakening coeff 1
of async motor 1
0.0
~
100.0
87%
×
F08.14
Field weakening coeff 2
of async motor 1
0.0
~
100.0
75%
×
F08.15
Field weakening coeff 3
of async motor 1
0.0
~
100.0
70%
×
F08.30
Autotuning of motor 1
0: No autotuning
0
×
1: Static autotuning of motor
2: Rotary autotuning of motor
Group F09 V/f Control Parameters of Motor 1
F09.00
V/f curve setting
0: Linear V/f
0
×
1: Multi-stage V/f
2: 1.2nd power V/F
3: 1.4th power V/F
4: 1.6th power V/F
5: 1.8th power V/F
6: 2.0nd power V/F
7: V/F complete separation
8: V/F half separation
9: 1.2 power inverse curve V/F
10:1.4 power inverse curve V/F
11:1.6 power inverse curve V/F
12:1.8 power inverse curve V/F
13:2.0 power inverse curve V/F
F09.01
Torque boost
0.1%–30.0% 0.0% (fixed torque
boost)
0.0%
△
F09.02
Cut-off frequency of torque
boost
0.00
~
Fmax
50.00Hz
△
F09.03
Multi-point V/F frequency
1(F1)
0.00
~
F09.05
0.00Hz
△
F09.04
Multi-point V/F voltage 1
(V1)
0.0
~
100.0
0.0%
△
F09.05
Multi-point V/F frequency
2(F2)
F09.03
~
F09.05
0.00Hz
△
F09.06
Multi-point V/F voltage 2
(V2)
0.0
~
100.0
0.0%
△
F09.07
Multi-point V/F frequency
3(F3)
F09.05
~
F09.09
0.00Hz
△
F09.08
Multi-point V/F voltage 3
(V3)
0.0
~
100.0
0.0%
△
F09.09
Multi-point V/F frequency
4(F4)
F09.07
~
rated motor frequency
50.00Hz
△
F09.10
Multi-point V/F voltage 4
(V4)
0.0
~
100.0 Ue=100.0%
100.0%
△
F09.11
V/F slip compensation
gain
0.0
~
300.0%
0.0%
△
F09.12
Stator voltagedrop
compensation gain
0.0
~
200.0%
100.0%
△