FR500F Series Special Purpose Inverter
- 12 -
when inverter running into any step, timer starts, and running to this step by acce/dece time,
after reach the step, inverter continue to run as this step until timing arrived at the time set by
this step, running figure as below:
0Hz
F0
T0
F1
F2
F3
F4
F5
T1
T2
T3 T4 T5 T6
Output
Frequency
(Hz)
F6
F7
T7
F8
T8 T9
F9
F10
T10
F11
T11
F12
T12
F13
T13
F14
T14
F15
T15
50Hz
Acc
Time
Figure 2-3 linear mode running diagram
2. Gradual Mode
Gradual mode can set 16 multi-steps in total, also can set the time from current step to next
step. When running, inverter gradually change to next step from current step, total consuming
time is the set time. When PLC running finished, inverter will stop according to dece time, running
diagram as below:
0Hz
F0
T0
F1
F2
F3
F4
F5
T1
T2
T3 T4 T5 T6
Output
Frequency
(Hz)
F6
F7
T7
F8
T8 T9
F9
F10
T10
F11
T11
F12
T12
F13
T13
F14
T14
F15
T15
50Hz
Figure 2-4 gradual mode running diagram
3: Length Mode
Frequency gradually changed from current speed to next setting speed, total consuming
length is set length(Length is calculated according to current frequency or to pulse input). When
PLC running finished, inverter stops according to the deceleration time, running diagram as
below: