TFC100 Rev180215
63
Figure W5. Manual ABF Selector Wiring
Figure W4. Electric Flush Valve Wiring
Manual ABF Selector TFC200 Only
The TFC200 system is available with an optional selector to make it a dual tank system. Four wires from
the micro-switches located on the manual ABF selector assembly need to be connected.
Two wires are connected to chassis ground, the other two wires are connected to the control module 6-Pin
connector, pin 3 - Select A/B Sensor and 12-Pin connector, pin 6 - Flush/Prime Switch.
6-Pin Valve Connector/Cable
PinWire
Description
1/Red
Close Valve (+)
2/Black Ground
3/Yellow
Close Limit Switch
4/Blue
Open Limit Switch
5/Brown
Limit Switch Return
6/Green
Open Valve (+)
Pins 2 and 5 are jumped
together in the cable harness.
Connect the cable to the foam pump
control 12-Pin Connector pins 5-9.
Closed for
Flush
Manual ABF Selector
Micro-Switches
GND
Closed for
B Foam
Both Opened
for A Foam
Control Module
12-Pin Connector Pin 6
Flush Switch
Control Module
6-Pin Connector Pin 3
Select A/B Sensor
Electric Flush Valve TFC300 (TFC100/200 Option)
This valve is standard on TFC300 models and is available as an option for the TFC100/200 single tank
systems. The valve is controlled by a pushbutton on the TFC300 control module and a separate mounted switch
and indicator for the TFC100/200 option. The valve cable is connected to the foam pump control.
Pin 1
Summary of Contents for Turbofoam TFC100
Page 69: ...TFC100 Rev180215 69 CONTROL MODULES Figure P1 TurboFoam Control Modules 6 7 5 4 3 2 1 ...
Page 81: ...TFC100 Rev180215 81 MANUAL ABF SELECTOR Figure P7 Manual ABF Selector 9 8 6 5 4 3 2 1 7 ...
Page 85: ...TFC100 Rev180215 85 NOTES ...
Page 86: ...TFC100 Rev180215 86 NOTES ...
Page 87: ...TFC100 Rev180215 87 NOTES ...
Page 88: ...TFC100 Rev180215 88 ...