![FRC Turbofoam TFC100 User Manual Download Page 26](http://html1.mh-extra.com/html/frc/turbofoam-tfc100/turbofoam-tfc100_user-manual_2329200026.webp)
TFC100 Rev180215
26
Set Discharge Flow Sensor ID Names (TFC200/300/400)
This code applies to systems with multiple foam discharge flow sensors and a summing box installed. There
are twelve (12) names along with a two digit number that can be used to identify each foam discharge flow sensor.
If no ID names are programmed for the sensors, the factory defaults are
FLOW 1, FLOW 2, FLOW 3
, etc.,
based on the location of each flow sensor input connection to the summing box(es)
The summing boxes are identified, when the code is selected, and shown on the control module display as
Sb #.#
(#'s refer to box and input). The following example shows two summing boxes with a total of nine inputs:
First box six inputs
Sb 1.1, Sb 1.2, Sb 1.3, Sb 1.4, Sb 1.5, Sb 1.6
Second box three inputs
Sb 2.1, Sb 2.2, Sb 2.3
.
The factory default ID name shown in the message display for the above example is
FLOW 1
through
FLOW 9.
Set Flow ID Name (Code P110)
Enter password code 1221. (Refer to Enter Password for Program Access.)
1. Press the
+
and
–
buttons and scroll to code P110.
2. Press the
PRESET
button.
Result: The
%
display shows
Sb 1.1
,
1.1
flashes indicating summing
box 1, input 1, message display shows the ID name.
3. Press the
PRESET
button (or press the
INC
or
DEC
button to scroll
inputs).
Result: The message display flashes the ID name.
4. Press the
+
and
–
buttons to scroll the ID names.
5. Press the
PRESET
button to choose a name.
Result: The message display flashes the ID number. (See Note)
6. Set the number (press the
+
and
–
buttons to change the digit, press
the
SELECT
button to move the curser to the next digit).
7. Press the
MENU
button to return to step 3.
8. Press and hold the
MENU
button for five (5) seconds to save.
MESSAGE
DISPLAY
DESCRIPTION
DIS.
##
Discharge
F DIS.
##
Front Discharge
REAR DIS
##
Rear Discharge
L/R DIS
##.
Left Rear
Discharge
R/R DIS.
##
Right Rear
Discharge
DECK GUN
##
Deck Gun
ROOF TUR
##
Roof Turret
CROSSLAY
##
Crosslay
PCON
##
Pre-Connect
L/R PCON
##
Left Rear
Pre-Connect
R/R PCON
##
Right Rear
Pre-Connect
FLOW
##
Factory default
ID name
Note:
If FRC flowmeters (DFA or FPA) are used to retrieve flow rate
information, only the FRC Datalink is connected to the foam system.
IMPORTANT
the flowmeter ID numbers must be different than the
flow sensor ID numbers used with a summing box.
Summary of Contents for Turbofoam TFC100
Page 69: ...TFC100 Rev180215 69 CONTROL MODULES Figure P1 TurboFoam Control Modules 6 7 5 4 3 2 1 ...
Page 81: ...TFC100 Rev180215 81 MANUAL ABF SELECTOR Figure P7 Manual ABF Selector 9 8 6 5 4 3 2 1 7 ...
Page 85: ...TFC100 Rev180215 85 NOTES ...
Page 86: ...TFC100 Rev180215 86 NOTES ...
Page 87: ...TFC100 Rev180215 87 NOTES ...
Page 88: ...TFC100 Rev180215 88 ...