Intelligence Setting
I
Use the Intelligence Control rotary switch to select Manual or Intelligent operation.
In Manual mode, the bar produces ionisation purely determined by the setting of
the Distance Control rotary switch.
In Intelligent mode, the bar continuously assesses the state of the charge on the
web and modifies the operating parameters of the bar to give optimal ionisation
under all conditions. It adjusts the polarity, duty cycle and frequency of the ion
emission to suit the application.
The Intelligence setting can double the neutralisation power of a XIFOS 33 bar in
Manual mode. XIFOS 33 Intelligence monitors the charge in the target and adjusts
the ion emission to achieve faster neutralisation. There are practical limits to the
sensing capability of the XIFOS 33 - if the electric field is weak or at a long distance
it will be more difficult to monitor.
Intelligence
Control
7.2 The Intelligence Control
Control
Position
Intelligence
Function
0
OFF
The bar operates in Manual mode.
1
ON
The bar operates in Intelligent mode.
Warning!
Turn off the bar when changing the setting.
7.