22
©
Fraser Anti-Static Techniques Ltd
2020
External PLC Input Type 1, Type 2 or Type 3
Interfacing to an external 24V IEC 61131-2 Type 1, Type 2 or Type 3 PLC digital
input can be achieved by direct connection.
External relay
An external relay can be connected for additional control/feedback applications.
Coil rating 24 V, 1.2 W max.
STATUS
OK
BLACK WIRE
WHITE WIRE
MAX 50 mA
PLC
4
2
11. Remote Interface and Wiring Examples
11.2 Example Applications
4
2
3
BLACK WIRE/STATUS
BLUE WIRE/0V & GROUND
MAX 50 mA
RELAY 24 V
RELAY 24 V
WHITE WIRE/
OK