![Fraser XIFOS 33 Operating Instructions Manual Download Page 24](http://html1.mh-extra.com/html/fraser/xifos-33/xifos-33_operating-instructions-manual_2329155024.webp)
24
©
Fraser Anti-Static Techniques Ltd
2020
Power Supply
Input voltage
24 V DC nominal, 21 - 28 V operating range. 0 V earthed.
Input current
2.5 A max.
Maximum input power
60 W
Input connector
M12, 5-pole, male
Output
Output voltage
±33 kV (-0/+10%)
Emitter material
Long-life, high-grade tungsten
Emitter touch current
100 μA max. per emitter
Monitoring
Endcap LED status
indication
Green flashing or scrolling: OK, bar is operating normally
Red/Green flashing: ‘Clean Me’ - attention required
Flashing Red: standby mode
Solid Red: supply voltage out of range or internal fault
Remote Monitor
Signalling outputs
‘OK’ and ‘Status’
Signalling levels
0 V / 24 V output
Output current
Sourcing (+24 V): 50 mA
Sinking (0 V): 50 mA
Limited to 50 mA max.
PLC
Compatibility
Compatible with IEC 61131-2 Type 1, 2 and 3 PLC inputs
Remote monitor states
Bar OK, ‘Clean Me’, Fault, Standby, Bar not powered
Protection
Internal protection
Under-voltage/over-voltage lockout, surge protection,
reverse supply polarity protection.
Over-temperature protection.
HV supplies protected against overload.
Signalling outputs protected against short-circuiting.
Environmental Conditions
Ambient temperature
0 - 55 °C
Relative humidity
Maximum 70 %, non-condensing
Ingress protection
IP64. Bar will not be damaged by exposure to water, but will not
function correctly if the emitters are bridged by moisture.
12. Specification and Dimensions