WARNING

 Capacitor voltage may be hazardous. To 

discharge motor capacitor, hold insulated handle 
screwdriver BY THE HANDLE and short capacitor 
terminals together. Do not touch metal screwdriver blade 
or capacitor terminals or electrical shock could occur. If in 
doubt, consult a qualified electrician.

Wire motor for correct 
voltage.  See “Electrical 

Installation” section of this 
manual and motor nameplate.

Ground motor before 
connecting  to power 

supply.

Meet National Electrical 
Code (NEC) or Canadian 

Electrical Code(CEC) and local 
codes for all wiring.

Follow all pump wiring 
instructions provided in 

this manual.

CAUTION

 

DO NOT touch an operating motor. The 

surface of the motor may be HOT. Allow the motor to cool 
for thirty (30) minutes before handling.

GENERAL SAFETY

Do not allow pump or any system component to freeze. 
To do so will void the warranty.
This pump has been evaluated for pumping water only. 
Pump liquids other than water may void warranty.
Periodically inspect pump and system components.

INTRODUCTION

A jet pump has advantages over other types of water 
systems. First, there are no moving parts in the well. All 
mechanical parts, motor, impeller, electrical controls, etc., 
are above ground within easy reach. If service is ever 
necessary, simple hand tools will do the job. This JET 
PUMP installs easily and quickly without the need for 
special tools or pump rigs. You can install it yourself 
provided you follow closely the instructions contained in 
this manual.

The Convertible VersaJet Series is designed for shallow 
well or deep well applications, and is capable of raising 
water from a depth of 25 feet maximum as a shallow well 
pump, and raising water from over 90 feet as a deep well 
pump. If there is insufficient pressure or flow for the 
desired application, consult the performance charts for 
the Convertible VersaJet pump to help determine if pump 
selection was made correctly. The Convertible VersaJet 
Series is capable of a wide range of pressures and flows, 
but changing the performance may require replacing the 
injector or the nozzle and venturi.

Hazardous voltage.
Can shock, burn, or
cause death.

Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor 
or tank.

WA R N I N G

INSPECT YOUR SHIPMENT

All jet pumps are carefully tested, inspected, and 
packaged to insure their arrival in perfect condition. When 
the pump is received, examine it closely to make sure 
there is no damage or broken parts that may have 
occurred in shipping. If damage is evident, report this 
immediately to your shipping carrier and dealer. The 
shipping carrier assumes full responsibility for the 
shipment’s safe arrival. Any claim for damage to the 
shipment, either visible or concealed, must be made 
through the shipping carrier first.  Notice that all 
Convertible VersaJet pumps are shipped without a 
suction flange installed.  This allows the end-user to more 
easily customize the installation to fit job specific 
application needs.  Franklin Electric offers several suction 
flange options, and these flanges must be ordered 
separately.  If you ordered an injector kit to go with this 
pump, the proper suction flange is supplied with that kit.

PREPARE PUMP FOR INSTALLATION

All Franklin Electric Convertible Jet Pumps are shipped 
without a suction flange installed.  A separate suction 
flange kit or injector kit should have been ordered in 
conjunction with this pump.  That kit contains instructions, 
document 106581101, for assembling the suction flange 
to the front of the pump.  Please perform that assembly 
before installing the pump to the well piping.  If you have a 
shallow well application, you will also need to assemble 
the injector to the front of the suction flange before 
installing the pump to the well piping.  Those instructions, 
document 106581102, are found with your injector kit.

GENERAL INSTALLATION

LOCATION OF PUMP
Decide on an area for the pump installation that is 
suitable based on the enclosure rating of the electric 
pump motor. All Convertible VersaJet pump motors 
are UL778 approved and will be marked 
“ACCEPTABLE FOR OUTDOOR or INDOOR USE.”
INDOOR PUMP INSTALLATION OPTION:
            
Choose a clean, well-ventilated, weatherproof location 
that affords protection from freezing, flooding, and 
excessive heat. In addition, it should provide access for 
servicing and allow convenient draining of the pump, 
tank, and service pipes. A prepared foundation is not 
essential, provided the surface is hard and level. It can be 
located in the basement or utility room of your house, at 
the well or between the house and the well. When 
freezing conditions are possible, the pump should be 
protected by auxiliary heat or drained completely of water 
to prevent damage.
OUTDOOR PUMP INSTALLATION OPTION: 
Choose a clean location best suited for the water system 
required. A prepared foundation is not essential, provided 
the surface is hard and level. It should provide access for 
servicing and allow convenient draining of the pump, 
tank, and service pipes. When freezing conditions are 

Summary of Contents for VersaJet Series

Page 1: ...otor or tank WARNING Hazardous voltage Can shock burn or cause death Ground pump before connecting to power supply Disconnect power before working on pump motor or tank WARNING CAUTION CAUTION WARNING...

Page 2: ...to make sure there is no damage or broken parts that may have occurred in shipping If damage is evident report this immediately to your shipping carrier and dealer The shipping carrier assumes full r...

Page 3: ...y have to be increased in diameter to reduce pressure loss The pressure loss in a system increases 1 As the flow rate increases 2 As the piping size decreases Consult included friction loss tables App...

Page 4: ...pumping of a low yield well Lower the injector assembly into the well It should be set at least 3 below the lowest dynamic water level if you are not using a tail pipe below the injector The foot val...

Page 5: ...e that has an alternate NPT pressure switch connection This alternate pressure switch connection allows the switch to read the pressure on the outbound side of the valve rather than inside the pump ca...

Page 6: ...mply with National Electric Code NEC or Canadian Electric Code CEC and all applicable local codes All dual voltage units come factory preset for 230 volts Figure 6 Disconnect power at electrical panel...

Page 7: ...filling the pump case completely full of water as damage may occur to the seal and other internal components if run dry PRESSURE SWITCH ADJUSTMENT EXAMPLE ASSUMES PRESSURE SWITCH IS INITIALLY SET WITH...

Page 8: ...g bolted to front of the pump If you need to service the impeller motor or seal use the following procedure going as far as needed to correct the problem 1 Disconnect the power to the unit 2 Disconnec...

Page 9: ...NT in this manual Increase size or clean out suction piping to pump Clear nozzle or impeller of clogging debris See PUMP DISASSEMBLY in manual Convert a shallow well application into a deep well arran...