PARTS FOR CONVERTIBLE VERSAJET PUMP

1A

6D

5C

5C

9E

2B

9E

5C,G

13G

11G

12G

5C,G

5C,G

18

9E

4F

10F

14H

15H

16H

5C

17F

9E

5C

5C

Number

Description

Kit Group 

Identifier

Repair Part Order Codes by Model Number

CVJ05CI

CVJ05CI-P

CVJ07CI

CVJ07CI-P

CVJ10CI

CVJ10CI-P

CVJ15CI

1

Motor

A

305374901

305374903

305374902

305374906

305374904

305374907

305374905

2

Studs

B

305465901

3

Bracket

4

O-Ring

F

305465902

5

Fasteners

C

305465903

6

Pressure Switch

D

305465904

7

Pressure Hose Fitting

8

Pressure Hose Tubing

9

Plugs

E

305465905

10

Mechanical Seal

F

305465902

11

Base Protector

G

305465906

12

Base Extension

13

Base

14

Impeller

H

305465907

305465908

305465909

305465910

15

Wear Ring

16

Diffuser

17

Grommet

F

305465902

N/A

Overhaul Kit*

I

305465911

305465912

305465913

305465914

18

Pump Face Plate

See Face Plate Ordering Table

*Overhaul Kit includes kits C, E, F, H

Summary of Contents for VersaJet Series

Page 1: ...otor or tank WARNING Hazardous voltage Can shock burn or cause death Ground pump before connecting to power supply Disconnect power before working on pump motor or tank WARNING CAUTION CAUTION WARNING...

Page 2: ...to make sure there is no damage or broken parts that may have occurred in shipping If damage is evident report this immediately to your shipping carrier and dealer The shipping carrier assumes full r...

Page 3: ...y have to be increased in diameter to reduce pressure loss The pressure loss in a system increases 1 As the flow rate increases 2 As the piping size decreases Consult included friction loss tables App...

Page 4: ...pumping of a low yield well Lower the injector assembly into the well It should be set at least 3 below the lowest dynamic water level if you are not using a tail pipe below the injector The foot val...

Page 5: ...e that has an alternate NPT pressure switch connection This alternate pressure switch connection allows the switch to read the pressure on the outbound side of the valve rather than inside the pump ca...

Page 6: ...mply with National Electric Code NEC or Canadian Electric Code CEC and all applicable local codes All dual voltage units come factory preset for 230 volts Figure 6 Disconnect power at electrical panel...

Page 7: ...filling the pump case completely full of water as damage may occur to the seal and other internal components if run dry PRESSURE SWITCH ADJUSTMENT EXAMPLE ASSUMES PRESSURE SWITCH IS INITIALLY SET WITH...

Page 8: ...g bolted to front of the pump If you need to service the impeller motor or seal use the following procedure going as far as needed to correct the problem 1 Disconnect the power to the unit 2 Disconnec...

Page 9: ...NT in this manual Increase size or clean out suction piping to pump Clear nozzle or impeller of clogging debris See PUMP DISASSEMBLY in manual Convert a shallow well application into a deep well arran...

Page 10: ...4 305374907 305374905 2 Studs B 305465901 3 Bracket 4 O Ring F 305465902 5 Fasteners C 305465903 6 Pressure Switch D 305465904 7 Pressure Hose Fitting 8 Pressure Hose Tubing 9 Plugs E 305465905 10 Mec...

Page 11: ...applicable codes ordinances and good trade practices 3 Product was not installed by a Franklin Certified Contractor or Franklin Key Dealer or 4 Product was damaged as a result of negligence abuse acc...

Page 12: ...106580101 Rev 2 07 13 9255 Coverdale Road Fort Wayne IN 46809 Tel 260 824 2900 Fax 260 824 2909 www franklinwater com...

Reviews: