background image

SHALLOW WELL DISCHARGE PIPING (FIGURE 2) 

The arrangement shown is typical and suitable for any 
pipe material, but all components shown are not required 
for proper use. The gate valves save draining the entire 
system when servicing the pump or pressure tank. There 
should be unions or other breakable pipe connections 
close to the pump to allow for easy accessibility when 
servicing.  If the side discharge ports in the pump case 
are used for discharge plumbing then the top discharge 
port can be used for priming.  If the top port is used for 
discharge plumbing, a plumbing tee may be required to 
provide a priming port for the system.

DEEP WELL TWIN PIPE INSTALLATION (FIGURE 3)

TWIN PIPE SUCTION PIPING
A twin pipe jet assembly is used on wells 4” and larger.  
Franklin Electric’s twin pipe injector requires a minimum 
1¼” suction pipe and minimum 1” drive water pipe.  Use 
of smaller pipes will increase system pressure losses and 
reduce the performance of the pump.  Horizontal offset 
piping may require using larger suction and drive water 

pipe sizes to minimize system pressure losses (see 
“HORIZONTAL OFFSET PIPING” above).

TWIN PIPE INJECTOR INSTALLATION
Prepare the twin pipe deep well injector for installation 
into the well as outlined in the instructions (document 
106581102) provided with the injector kit (ordered 
separately).  The foot valve strainer can be installed onto 
the bottom of a 34’ tail pipe, rather than the bottom of the 
injector, to prevent over pumping of a low yield well.  
Lower the injector assembly into the well.  It should be 
set at least 3’ below the lowest dynamic water level if you 
are not using a tail pipe below the injector.  The foot valve 
strainer should be no closer than 3’ from the bottom of 
the well.
Priming will be easier if you fill the pipes with water 
before attaching the pump.  Make sure that all piping 
slopes upward towards the pump and that no point is 
above the pump suction.  Connect the suction and drive 
water pipes to the threaded connections on the pump 
suction flange.  Always double clamp barbed connectors.
Go to “DEEP WELL DISCHARGE PIPING” below.

DEEP WELL PACKER INSTALLATION (FIGURE 4)

PACKER SUCTION PIPING
Packers use the area between the ID of the 2” well 
casing and the OD of the 1¼” suction pipe as the drive 
water (pressure) piping.  The ID of the 2” well casing 
must be smooth and clean to insure a good seal with the 
packer leathers.   Turned couplings should be used for 
the 1¼” suction pipe to increase clearance between the 
ID of the 2” well casing and the coupling, and reduce 
pressure losses in the drive water piping.
PACKER INSTALLATION
Prepare the packer for installation into the well as 
outlined in the instructions (document 106581102) 
provided with the packer kit (ordered separately).

Unions

Pump & Motor

Assembly

1-1/4

 Suction Pipe

Sanitary Well Seal

4

 or Larger Well Casing

Twin Pipe Injector

1

 Drive Pipe

Optional Tail Pipe

Foot Valve

Unions

Pump & Motor

Assembly

1-1/4

 Suction Pipe

1

 Drive Pipe

Well Adapter

2

 Well Casing

1-1/4

 Suction Pipe

2

 Packer

Foot Valve

Optional Tail Pipe

Pressure Switch

Union

Service Pipe

Gate Valve

Pressure Tank

Pump & Motor 

Assembly

Summary of Contents for VersaJet Series

Page 1: ...otor or tank WARNING Hazardous voltage Can shock burn or cause death Ground pump before connecting to power supply Disconnect power before working on pump motor or tank WARNING CAUTION CAUTION WARNING...

Page 2: ...to make sure there is no damage or broken parts that may have occurred in shipping If damage is evident report this immediately to your shipping carrier and dealer The shipping carrier assumes full r...

Page 3: ...y have to be increased in diameter to reduce pressure loss The pressure loss in a system increases 1 As the flow rate increases 2 As the piping size decreases Consult included friction loss tables App...

Page 4: ...pumping of a low yield well Lower the injector assembly into the well It should be set at least 3 below the lowest dynamic water level if you are not using a tail pipe below the injector The foot val...

Page 5: ...e that has an alternate NPT pressure switch connection This alternate pressure switch connection allows the switch to read the pressure on the outbound side of the valve rather than inside the pump ca...

Page 6: ...mply with National Electric Code NEC or Canadian Electric Code CEC and all applicable local codes All dual voltage units come factory preset for 230 volts Figure 6 Disconnect power at electrical panel...

Page 7: ...filling the pump case completely full of water as damage may occur to the seal and other internal components if run dry PRESSURE SWITCH ADJUSTMENT EXAMPLE ASSUMES PRESSURE SWITCH IS INITIALLY SET WITH...

Page 8: ...g bolted to front of the pump If you need to service the impeller motor or seal use the following procedure going as far as needed to correct the problem 1 Disconnect the power to the unit 2 Disconnec...

Page 9: ...NT in this manual Increase size or clean out suction piping to pump Clear nozzle or impeller of clogging debris See PUMP DISASSEMBLY in manual Convert a shallow well application into a deep well arran...

Page 10: ...4 305374907 305374905 2 Studs B 305465901 3 Bracket 4 O Ring F 305465902 5 Fasteners C 305465903 6 Pressure Switch D 305465904 7 Pressure Hose Fitting 8 Pressure Hose Tubing 9 Plugs E 305465905 10 Mec...

Page 11: ...applicable codes ordinances and good trade practices 3 Product was not installed by a Franklin Certified Contractor or Franklin Key Dealer or 4 Product was damaged as a result of negligence abuse acc...

Page 12: ...106580101 Rev 2 07 13 9255 Coverdale Road Fort Wayne IN 46809 Tel 260 824 2900 Fax 260 824 2909 www franklinwater com...

Reviews: