F3D3
Series
Service Manual - Factory Lev3 Parameter Access / 1.11.2
Questions? Call Franke Technical Support Group For Your Area. Copyright
2012 Franke, Inc. All rights reserved.
Parameter Access & Programming
F3D3 Series Fries Dispensers provide easy
access to Factory Level operating and
service diagnostic parameters using the
front operator interface touch panel &
display. To access:
1)
Leave unit plugged in.
2)
Turn Main Power Switch
ON
.
3)
Lane power must be
OFF
. Display will
be blank or show current freezer
temperature, depending on the lane.
To Access Factory Level 3 Parameters:
Step
Action Required
Resulting Display
1
From Standby condition use 3
rd
touchpad to
enter:
3 3 3 3
. [The Entry Code]
Special Mode Select
Cust Fact Exit
2
Press touchpad 2 = Fact(ory)
Factory Access Level
Lev1 Lev3 Exit
3
Press touchpad 2 = Lev3
Password ??
Enter Password
0
_ _ _
Inc OK Exit
4A
Press touchpad 2 = OK [Icon will move right to
next digit]
Password ??
Enter Password
0
0
_ _
Inc OK Exit
4B
Press touchpad 2 = OK [Icon will move right to
next digit]
Password ??
Enter Password
0 0
0
_
Inc OK Exit
4C
Press touchpad 2 = OK [Icon will move right to
last digit], then:
Password ??
Enter Password
0 0 0
0
Inc OK Exit
4D
Press touchpad 1 = Inc once, to raise to 1,
then:
Password ??
Enter Password
0 0 0 1
Inc OK Exit
5
Press touchpad 2 = OK
Language [first Parameter]
P01 = English
++ -- ->
See Parameter
Spreadsheet
for P-numbers, functions & default settings.
NOTE Software Codes and exceptions that apply.
Notes:
Command Key: ++
to scroll up;
--
to scroll down;
->
to move flashing
underscore __ under next value;
==
to accept or OK value or setting
P02
Set Point
Example:
Press 1 =
++
to increase temp. value [-000
4
]
Press 2 =
--
to decrease temp. value [- 000
6
]
Press 3 =
==
to accept (new) setting
Set Point [Refrigerator temp.]
P02 = -000
5
F
++ -- ==
Rev. 1 11/2012
NOTE: All programming is done using the
three choice buttons labeled: 1, 2 and 3 above.
1
2
3