FPS PowerSewer V4PS Installation, Operation & Maintenance Manual Download Page 29

29

POWERSEWER® 3 YEAR WARRANTY STATEMENT

LIMITED WARRANTY

THIS WARRANTY (“WARRANTY”) SETS FORTH THE COMPANY’S SOLE OBLIGATION AND PURCHASER’S EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT.

Franklin Electric Co., Inc. and its subsidiaries (the “Company”) warrants that the products accompanied by this Warranty are free from defects in materials or workmanship that exist at 
the time of sale by the Company and which occur or exist within the applicable warranty period identified below. Any distributor, sub-distributor, recipient, end-user and/or consumer 
agrees that by accepting the receipt of the products, the distributor, sub-distributor, recipient, end user and/or consumer expressly agrees to be bound by the terms of this Warranty.

I. Applicable Warranty Period

The products accompanied by this Warranty shall be covered by this Warranty for a period of 36 months from the date of original purchase. In the absence of suitable proof of 
purchase date, the warranty period of this product will begin to run on the product's date of manufacture.

III. Replacement Parts

1. 

Replacement parts will receive a 12-month warranty from the date of purchase.

III. Instructions Applicable to this Limited Warranty

1. 

Consumers wishing to submit a warranty claim must return the products accompanied by this Warranty to the point of purchase for warranty consideration.

2. 

Consumer must retain proof of purchase and installation documents. Installation documents to be completed by Service Representative at the time of unit start-up.

3. 

Upon discovery of a potential defect, any personal injury, property damage or any other type of resulting damage, if applicable, shall be reasonably mitigated to the extent possible.

4.  Consumer must notify the Company or Service Representative within two (2) days after discovering a potentially defective product or part.
5. 

All warranty service or repair must be performed by the Company or a Service Representative.

6.  All return of parts to the Company for evaluation and/or repair should be made through a Service Representative. If you are not sure of the Service Representative  

in your area, call toll free 1-866-271-2859.

7. 

At its discretion, the Company may inspect products either at its facilities or in the field, and after determination of a warranty claim, will, at its option, repair or replace 
defective parts. Repaired or replaced parts will be returned freight prepaid by the Company.

8. 

This Warranty does not cover any labor or shipping charges. The Company shall not be liable for any costs or charges attributable to any product testing, maintenance, 
installation, repair or removal, or for any tools, supplies, or equipment needed to install, repair, or remove any product.

IV. Limitations Applicable to this Limited Warranty
THIS WARRANTY DOES NOT APPLY TO ANY OF THE FOLLOWING:

1. 

Any product on which any maintenance or repair service is performed by any person other than the Company or a Service Representative authorized by the Company  
(“Service Representative”);

2. 

Any product that is not installed, applied, maintained and used in accordance with the Company's published instructions, applicable codes, applicable ordinances  
and/or with generally accepted industry standards.

3. 

Any product that has been subject to misuse, misapplication, neglect, alteration, accident, abuse, tampering, acts of God (including lightning), acts of terrorism,  
acts of war, fire, improper storage or installation, improper use, improper maintenance or repair, damage or casualty, or to an excess of the recommended  
maximums as set forth in the product instructions.

4.  Any product that is operated with any accessory, equipment, component, or part not specifically approved by the Company.
5. 

Use of replacement parts not sold by the Company, the unauthorized addition of non-Company products to other Company products,  
and the unauthorized alteration of Company products.

6.  Products damaged by normal wear and tear, normal maintenance services and the parts used in connection with such service, or any other  

conditions beyond the control of the Company.

7. 

Any product that has been used for purposes other than those for which it was designed and manufactured.

8. 

Any use of the product where installation instructions and/or instructions for use were not followed.

9.  Products connected to voltage other than indicated on the product’s nameplate.
10.  Products where the pump was exposed to any of the following: sand, gravel, cement, grease, plaster, mud, tar, hydrocarbons, hydrocarbon derivatives  

(oil, gasoline, solvents, etc.) or other abrasive or corrosive substances.

11.  A pump, which is not activated within two months of installation, unless the Company or a Service Provider provides service to the pump before activation.  

The cost of this service is the responsibility of the owner.

12.  Products in which the pump has been used for pumping of liquids above 140°F.
13.  Products in which the pump was allowed to operate dry (fluid supply cut off).
14.  Products in which the sealed motor housing has been opened or the product has been otherwise dismantled by customer.

Summary of Contents for PowerSewer V4PS

Page 1: ...V4PS Installation Operation Maintenance Manual...

Page 2: ...and maintenance instructions may result in electrical shock or fire hazard personal injury or death unsatisfactory performance equipment failure and will void the warranty If you have any questions ca...

Page 3: ...ng the Vent 11 7 1 Vent Coupling Location 7 2 Vent Cap Location 7 3 Vent Pipe Slope 7 4 Solvent Cementing Vent Piping and Fittings 7 5 Installing the Remote Vent Cap 8 Locating and Mounting the Contro...

Page 4: ...for Field Installation Fiberglass Basin Cover Wet well access cover with polyethylene seal using 3 8 16 SST bolts to fasten cover to basin Spring Release Float Tree Assembly SST Isolated Pump Support...

Page 5: ...or removal of the manhole bolts and cutting ring bolts 1 Phillips screwdriver to open the control panel cover Small flathead screwdriver used to connect wire to control panel Wire strippers Small chan...

Page 6: ...tallation should be suspended until the extent of the damage can be determined by an authorized Franklin Electric representative Any field repairs or alterations must be authorized in writing by Frank...

Page 7: ...aggregate for collection tank foundation Concrete for collection tank ballast minimum 7 cubic feet Approved backfill materials see section 10 1 Approved Backfill Materials Determine main electrical su...

Page 8: ...im should be at least 1 1 2 above final grade The final grade should slope away from the collection tank to avoid surface water from ponding on or around the collection tank and cover NOTICEDo not ins...

Page 9: ...ary 4 4 Applying Solvent Cement Solvent cement must be applied immediately to the primed surfaces before the primer dries in an alternating three coat application Using a brush or applicator sized no...

Page 10: ...e Then dry fit service lateral from property into elbow or sanitary tee Make any necessary adjustments to the drop inlet pipe for a proper fit NOTICEIf a cleanout is not available in the property serv...

Page 11: ...utlined in section 4 0 Solvent Cementing Joints NOTICEJoints and fittings in the vent piping must be watertight If not ground and surface water could infiltrate the PowerSewer system resulting in unne...

Page 12: ...ause fire or damage to the pump control panel or cause severe personal injury and will immediately void the warranty Control Panel for Pump Power Wiring Preparation Strip back the outer jacket of the...

Page 13: ...as defined by ASTM D 2321 include clean gravels and sands with less than 5 fines and clean compactible soil that contain less than 12 fines Class 2 materials consist of rounded materials and are less...

Page 14: ...e junction box The length of the power cord is 10 long regardless of the size of the tank Do not leave extra cord inside of wet well The cable may become entangled in the rotating cutters or interfere...

Page 15: ...tor features with the property owner 12 OPERATION The PowerSewer grinder pump sewer system is equipped with a float control system that continuously controls the grinder pump operation 12 1 Automatic...

Page 16: ...List Equip yourself with the proper installation operation and maintenance tools before performing any work on or near the PowerSewer system Review section 1 2 Installation and Maintenance Tool List...

Page 17: ...draulic Diaphragm Seal TPV Pump Stand Off PVC 1 1 4 Discharge Pipe SST 2 HP Centrifugal Grinder Pump IGP M IGP A IGPH M IGPH A IGPDS M IGPDS A Discharge Depth See Table A Basin Height See Table H 42 1...

Page 18: ...ll Bearing Upper Single row ball 6203 Ball Bearing Lower Single row ball 6306 Seal Housing Cast iron with epoxy coating Mechanical Seal Carbon Ceramic Volute Cast iron with epoxy coating Impeller Bras...

Page 19: ...and third party approval Motor Cover Cast iron with epoxy coating Motor Cover O ring Nitrile Motor Design Single phase capacitor start capacitor run or three phase depending on pump model Insulation C...

Page 20: ...hes must be rated a minimum of 2 Amps at 120 V 208 230 VAC PUMP POWER CABLE 208 230 VAC 115 VAC 1 PHASE 60 HERTZ POWER SUPPLY CONTROL PANEL 515351 515357 COMMON RUN START PANEL GRD BLUE BLACK ORANGE B...

Page 21: ...60 C copper wire minimum 6 Level switches must be rated a minimum of 2 Amps at 120 V THREEPHASE IGP IGPHMANUALGRINDER Wiring Diagram 208 240 480 600 VAC 3 PHASE 60 HERTZ POWER SUPPLY INCOMING POWER CO...

Page 22: ...Ball Bearing Upper Single row ball 6203 Ball Bearing Lower Single row ball 6306 Seal Housing Cast iron with epoxy coating Mechanical Seal Carbon Ceramic Volute Cast iron with epoxy coating Impeller Br...

Page 23: ...Motor Design Single phase capacitor start capacitor run Insulation Class F Overload Protection Internal on winding thermal protector Motor Shaft AISI 300 series stainless steel Ball Bearing Upper Sin...

Page 24: ...M FLOAT BLACK BLACK BLACK WHITE WHITE WHITE GREEN WHITE BLACK TANK JUNCTION BOX MOUNTED IN TANK DRY WELL NOTE This is a control drawing only and does not re ect the actual locations of cable penetrati...

Page 25: ...with fluoroelastomer FKM bellows and stationary ceramic with fluoroelastomer FKM O ring Lower Type 21 spring loaded rotating silicon carbide with fluoroelastomer FKM bellows and stationary silicon car...

Page 26: ...RUN START SEAL FAIL PUMP OFF FLOAT PUMP ON FLOAT HIGH LEVEL ALARM FLOAT TANK JUNCTION BOX MOUNTED IN TANK DRY WELL SENSOR CABLE NOTE This is a control drawing only and does not re ect the actual locat...

Page 27: ...TANK JUNCTION BOX MOUNTED IN TANK DRY WELL 12 AWG PUMP CABLE 125 FT MAX COMMON RUN START TB4 SEAL FAIL 18 AWG FLOAT CABLE 18 AWG SEAL FAIL CABLE NOTE This is a control drawing only and does not re ect...

Page 28: ...t check valve not provided shown for reference only 10 Stop valve not provided shown for reference 11 Force main or gravity line 12 Pump power and or control float control direct bury cable or continu...

Page 29: ...ty does not cover any labor or shipping charges The Company shall not be liable for any costs or charges attributable to any product testing maintenance installation repair or removal or for any tools...

Page 30: ...RN AND OR INSTRUCT LOSS OF OTHER PRODUCTS OR COSTS OF ENVIRONMENTAL REMEDIATION OR DIMINUTION IN PROPERTY VALUE THE REMEDIES OF THE PURCHASER SET FORTH HEREIN ARE EXCLUSIVE AND THE LIABILITY OF THE CO...

Page 31: ...31 NOTES...

Page 32: ...Road Fort Wayne IN 46809 Tel 866 271 2859 Fax 886 281 2709 www franklinengineered com Form 998076 Rev 002 12 20 For technical assistance please contact 866 271 2859 www franklinengineered com FPSEngin...

Reviews: