GreenFire GF75-1 BioEnergy Stove
23
MAINTENANCE
MAINTENANCE
Minimum Burning Capacity
8,500 BTU/h (when burning wood pellets)
1
lb/h
Maximum Burning Capacity
34,000 BTU/h (when burning wood pellets)
4 lb/h
Effi ciency of the Burn-pot
Approximately
85%
Combustion Fan
Power varies from 25 CFM to 45 CFM
Convection Fan
Power varies from 35 CFM to 125 CFM
Fuel Hopper
Maximum capacity of 75 lb (34 kg)
Certifi cation
UL, ULC, CE and EPA
Air Emissions (EPA)
0.6
g/h
Power Settings
5 levels of heat
Electrical
Min. Capacity .25 amps (120 volts)
120 volts or 240 volts AC
.15 amps (240 volts)
Max. Capacity .65 amps (120 volts)
.35 amps (240 volts)
12 volts DC
Min.
Capacity
1.8 amps (13.8 Volts DC)
Max. Capacity
4.5 amps (13.8 Volts DC)
In stop mode
120 Volts or 240 Volts (.05 amps or .07 amps)
13.8 volts DC (.03 amps)
GF75-1 Dimensions
Height
40.5"
(1029
mm)
Width
26.5"
(673
mm)
Depth
25.25"
(641
mm)
Weight
Approximately 305 lb (138 kg)
Type of Chimney
FPI recommends the use of corn venting
for
all
applications.
Diameter of the Chimney
3" (76 mm) of interior diameter
GF75-1 TECHNICAL DATA