Heating
cont.
DROP-IN HEATED WELL ASSEMBLIES - SERVICING
Temperature
Probe
The temperature probe for the controller is
located on the base of the well.
Remove this panel from the underside of
the well to access the probe.
Over
Temperature
Cut Out
The over temperature cut out is mounted on the side of the well, within the
power connection enclosure.
Water Level Control
DROP-IN HEATED WELL ASSEMBLIES
-
SERVICING
Indicator
Module
The electronic water sensing module is located behind the control panel.
It is connected to the sensing probes and the “water Low” indicator lamp.
Water Sensing
Probes
The water sensing probes are located at various heights in the side of the well.
An earth reference connection is also made to the well wall.
Auto-fill
Some models have auto-fill water control valves, see Mechanical Drawings.
The water valve is operated by the water level sensing module.
Adjust the flow control valve, to achieve an appropriate fill rate.
A sediment trap is fitted on the inlet side of the valve, to avoid malfunction.
Mains Lead
DROP-IN HEATED WELL ASSEMBLIES
-
SERVICING
Lead
Replacement
If damaged, the mains lead must ONLY be replaced by a qualified service
person.
Summary of Contents for IN-GNH03
Page 1: ...Inline GN Series Heated Well...
Page 29: ...IN GNH03 4 5 6 8 29 Future Products Group IN GNH08...
Page 31: ...IN GNH03 4 5 6 8 31 Future Products Group Flush Mount Installation...
Page 32: ...Part No 21966 Rev M February 2016 32 Heated Well GN Series Under Mount Installation...
Page 34: ...Part No 21966 Rev M February 2016 34 Heated Well GN Series...