IN-GNH03/4/5/6/8
- 13 -
© Future Products Group
TROUBLE SHOOTING
FAULT
POSSIBLE CAUSE
REMEDY
Well does not operate/start
The mains isolating switch is
off, a circuit breaker or fuses
are off at the power board
Turn isolating switch On.
Check external circuit breaker
or fuses in the mains supply
External RCD has tripped
Eliminate leakage current
and reset RCD
The On/Off switch is in the Off
position
Turn control knob to On
Internal MCB has tripped
Have wiring checked and
reset MCB
Well does not reach
temperature
Controller setting disturbed
Re-set controller and re-test
after thirty minutes
Controller is faulty
Have controller replaced
An element is blown
Have the element replaced
Overhead lights not working
(If fitted)
The light switch is OFF
Turn light switch ON
Halogen lamp has failed
Replace lamp
Condensation on lamps
Ensure lamps are ON
whenever steam is present
Internal MCB has tripped
Have wiring checked and
reset MCB
Metal parts corroded
Caustic detergent damage
Order replacement parts
Mineral Deposits on elements
Poor water quality
Condition water supply
Excess water flow (auto-fill)
Incorrect flow valve adjustment
Adjust flow valve
Reduced water flow (auto-fill)
Blocked water sediment trap
Empty sediment trap
Service
Personnel Only
The table entries in
italics
indicate actions to be taken only by qualified Service
Personnel.
Summary of Contents for IN-GNH03
Page 1: ...Inline GN Series Heated Well...
Page 29: ...IN GNH03 4 5 6 8 29 Future Products Group IN GNH08...
Page 31: ...IN GNH03 4 5 6 8 31 Future Products Group Flush Mount Installation...
Page 32: ...Part No 21966 Rev M February 2016 32 Heated Well GN Series Under Mount Installation...
Page 34: ...Part No 21966 Rev M February 2016 34 Heated Well GN Series...