Part No.21966 Rev. M February 2016
- 12 -
Heated Well GN Series
Preparation
DROP-IN HEATED WELL ASSEMBLIES
-
OPERATION
Power Supply
Ensure that power is connected to the cabinet.
Decide on the
Required Mode
If wet or steam operation is to be used, first add water to cover the elements.
The correct water level for the various modes is shown on the depth gauge, on
the inside of the well.
Turn the mode selector to the appropriate setting, to start heating up the well.
The level indicator lamp should be off and the element indicator on.
Caution
Turn on Lights
If fitted
It is important to turn on the overhead heat lamps, whenever steam is escaping
from the heated well, whilst pre-heating and during normal operation.
If this is not done, condensation will cause premature lamp failure.
Pre-heat the
Well
Set the temperature controller to the required setting and allow the well to reach
the required operating temperature, with dishes in place, before adding food.
The well temperature is indicated on the controller display, and the Element On
indicator lamp will extinguish when the set temperature is reached.
To reduce the pre-heating time, the well can be filled with hot water.
NOTE
Setting the controller to a higher temperature than required will not
speed up the heating process.
Set it to the desired temperature.
Fumes and
Odours
Before first use, operate the cabinet for 4 hours to remove any fumes or odours,
which may be present. This will avoid possible tainting of food.
Load Food
Load with
pre-heated
food products.
When correctly set, the temperature of pre-heated products will be held above
65
C.
This is not an oven, so do NOT place cold products in the dishes.
Monitor
Temperatures
It is important to regularly monitor the temperatures of the food in the dishes.
Trim the electronic controller setting, as necessary, to obtain the required
temperature.
Monitor Water
Level
Monitor the water level indicator lamp, and if the lamp comes on, add more
water to restore the correct level for the chosen operating mode.
Summary of Contents for IN-GNH03
Page 1: ...Inline GN Series Heated Well...
Page 29: ...IN GNH03 4 5 6 8 29 Future Products Group IN GNH08...
Page 31: ...IN GNH03 4 5 6 8 31 Future Products Group Flush Mount Installation...
Page 32: ...Part No 21966 Rev M February 2016 32 Heated Well GN Series Under Mount Installation...
Page 34: ...Part No 21966 Rev M February 2016 34 Heated Well GN Series...