14
Battery data
Battery level indicator at 0-24%, 25-49%, 50-74%, and 75-100% of its capacity
In battery mode, the number of bars shows the remaining charge
In line mode, the number of bars indicates how much charge it will need to reach its full
capacity
In AC mode, the battery state of charge is displayed
Status
Battery voltage
LCD Display
Constant Current
mode / Constant
Voltage mode
<2V/cell
4 bars will flash alternatively
2 ~ 2.083V/cell
Bottom bar will be on and the other
three bars will flash alternatively
2.083 ~ 2.167V/cell
Bottom two bars will be on and the other
two bars will flash alternatively
> 2.167 V/cell
Bottom three bars will be on and the top
bar will flash
Float stage: maintains batteries in a fully
charged state
4 bars will be on
In battery mode, the remaining capacity is displayed
Load percentage
Battery voltage
LCD Display
Load >50%
< 1.717V/cell
1.717V/cell ~ 1.8V/cell
1.8 ~ 1.883V/cell
> 1.883 V/cell
50%> Load >
20%
< 1.817V/cell
1.817V/cell ~ 1.9V/cell
1.9 ~ 1.983V/cell
> 1.983
Load < 20%
< 1.867V/cell
1.867V/cell ~ 1.95V/cell
1.95 ~ 2.033V/cell
> 2.033
Load information
Displays the inverter shutdown due to an overload
Indicates the load level compared to the inverter’s maximum load capacity in
increments of 0-24%, 25-49%, 50-74% and 75-100%
0%~24%
25%~49%
50%~74%
75%~100%
Summary of Contents for FIO-P11K12