11
When item 38 is set as disable, this could be used to send a signal to an external device when the battery voltage
reaches the warning level (default setting):
When item 38 is set to enable, and the unit is operating in battery mode, it could be used to trigger the grounding circuit
to connect the neutral and grounding of the AC output together.
Unit status
Condition
Dry contact terminals:
Normally closed (NC) Common (C)
Normally open (NO)
State
NC and C
NO and C
Power off
The inverter is off, and no power is supplied to the output
Close
Open
Power on
The output is being powered from an AC source
Close
Open
The output
is powered
from either
battery or PV
energy
Item 01 set
as Utility
Battery voltage < low DC warning
voltage
Open
Close
Battery voltage > Setting value in
item 13 or battery charging has
reached float stage
Close
Open
Item 01 is set
as SBU (solar
priority)
Battery voltage < Setting value in
item 12
Open
Close
Battery voltage > Setting value in
item 13 or battery charging has
reached float stage
Close
Open
Unit status
Condition
Dry contact terminals:
Normally closed (NC) Common (C)
Normally open (NO)
State
NC and C
NO and C
Power off
The inverter is off, and no power is supplied to the output
Close
Open
Power on
The inverter operates in standby mode, line mode or fault mode
Close
Open
The inverter operates in battery mode
Open
Close