13 TROUBLESHOOTING GUIDE
List of possible troubles is given in Table 13.1.
Table 13.1
Trouble
Possible Cause
Repair
1. The receiving- control
device
constantly
generates an alarm.
1.
Disconnection
in
actuating relay circuit.
Check the cable integrity and
the
accuracy
of
its
connection.
2. The supply voltage is
absent or below the norm.
Provide the necessary supply
voltage of the sensor.
3.
The
protected
area
doesn’t meet the necessary
requirements.
Inspect the protected area
according
to
the
requirements of the issue 8
and remove the defects.
4. The transmitter-receiver
unit is out of order.
Replace
the
transmitter-
receiver unit.
2. False alarms.
1. Moving objects in the
detection zone.
Inspect
the
sector
and
remove interference factors.
2. Animals movement in the
sector.
3. Too high sensitivity.
Align the sensor according to
the issue 9.
3. The sensor does not
generate alarms when an
intruder
crosses
the
detection zone.
1. Too low sensitivity.
Align the sensor according to
the issue 9.
2. The transmitter-receiver
unit is out of order.
Replace
the
transmitter-
receiver unit.