passages should be made in the second half of each subzone. The subzones, where it is
physically impossible make control passages, are not configurated.
After you have set up the signal gain, the noise level should not be higher than 20% of the
full scale.
To set up the thresholds in each subzone by means of control passages please go from the
mode «Operation/Settings» to the mode «Operation». The optimal threshold is that which is
10…15% less than the maximum signal caused by a person.
The control passages are to make at the full height or bent over with the minimal and
maximal speed (0,3…8 m/s).
At the final stage please set the approved passages switching off subzones 4 and 5.
A sample of such configuration is given in Fig. 10.15.
Fig. 10.15
Doing the control passages check the detection zone configuration.
When the checking and adjustment are over, click «Save to Memory» to save the
configuration in the nonvolatile memory of the sensor and to switch OFF the computer.
In the mode «PC Control» the built-in indicator «Alarm» generates the short lights
with duration of 0.25 sec and interval of 4 sec.
The remote control of the sensor implements by means of the interface RS-485. It is
connected to the PC via interface converter which is delivered on request. The operation
principle via RS-485 is equal to operation via USB-cable.