7 SAFETY MEASURES
7.1 The current safety standards for the operation with electrical facilities with the voltage up
to1000 V should be observed during mounting, preventive maintenance and repair of the
sensor.
7.2 Cables should be laid, terminated and connected to the sockets only when the supply
voltage is OFF.
7.3 The power of the super high frequency energy, beaming by the sensor satisfies the
security standards and doesn’t have deleterious effect on human health.
7.4 It is prohibited to mount and maintain the sensor at thunderstorms.
7.5 Installation and maintenance of the sensor should be performed only by people, who
underwent special safety trainings.
7.6 The breach of requirements of this user manual can provoke the sensor breakdown.
8 MOUNTING
8.1 Requirements to the protected area.
The choice of the place and the correct sensor mounting on the protected sector or in
the protected room are the basic factors, which provide its operational reliability.
Please use the protective visor if using the sensor outdoor.
Fasten the visor on the case of
the sensor with two screws 3,9x19 containing in the delivery kit as shown in Fig. 6.1.
The input cable should be threaded through the corrugated pipe.
If you use a junction
box, insert a cable gland in it and connect the corrugated pipe to the cable gland.
The protected site should meet the following requirements:
a) height of irregularities should not exceed ±0,3m.Otherwise the characteristics of the
sensor can worsen and the application of the sensor is determined by the trial operation
b) the protected site is to clear of high grass (if higher than 0,5 m), bushes and tree branches
at the distance of 5 m minimum from the detection zone border
c) big objects moving under wind (wings of a gate, tumbledown fences, etc.) should not be
located in the detection zone and out of the detection zone at the distance of 10 m minimum
d) the grass height should not exceed 0,2 m
e) the snow height should not exceed 0,3 m
f) movement of people and animals are not permitted at the distance 5…10 m minimum from
the detection zone borders
g) to eliminate movements of people and animals in the detection zone, it is recommended to
enclose the detection zone with a fence (from 1 m height)
h) roof runoff should not be near the sensor enclosure at sensor installation on an outside
wall.