Forno Bravo
112
©Forno Bravo, LLC 2019. All Rights Reserved.
Ver. 2.0
19"
16"
55"
Recommended minimum with
no brick arch or landing
26"
Minimum from hearth
34"-41"
Recommended
minimum
CMU stand
with gas burner
Burner unit
Minimum 3-1/2" hearth
with rebar
Allow for decorative facade
*(see chart)
Allow 3" for insulation
24" Stainless steel flue
with 8" interior,
anchor plate and rain cap
Burner control unit
55"
Recommended
minimum
50"
54"
Recommended minimum
Allow 1" Clearance all
the way around side walls
Burner unit
Decorative facade
Predrilled
thermocouple
location
39-1/2" Cooking
surface
54"
19-3/4"
*(Minimum)
34"-41"
Recommended
19-3/4"
*(Minimum)
* A minimum
19-3/4"W x 19-3/4"H opening
is required for air flow to burner assembly
Front View
Side Elevation
For more information: www.fornobravo.com
Shown with non-combustible hearth
UL737, UL2162, NSF-4, CAN/CGA-1.8 Dual,
ANSI-Z83.11 Dual, ANSI-Z21.58, CSA 1.6-2007 Listed
Installation guide: www.fornobravo.com/PDF/residential_install.
Made in the U.S.A.
Residential Gas Fired Pizza Oven
1
2
3
4
Revision
Sheet: of
6/13/2016
3
7
Architect Drawings
Concrete Masonry Unit (CMU)
Casa2G 100G
SKU: CMU
Crate ships 45"W x 48"L x 47"H; Oven weight: 1100 lbs..
24" Stainless steel flue with 8" interior, rain cap and anchor plate comes standard
Wood, liquid gas or propane fuel;
Specifications:
Non-combustible hearth.
36" from front of oven landing to combustibles;
30" Side clearance from door opening;
14" above completed dome assembly;
1" clearance all the way around side walls;
Clearance to combustibles:
Refer to Gas Burner Drawing for air, & access requirements
Gas Requirements:
Top View