Service / Repair
Vacuum / Pressure Troubleshooting
If the vacuum or pressure appears to be weak or non-existent check the following.
Raise and lock the mould
table in the up position
Turn your machine on
and press the Start button
Check the reading you
get on the vacuum gauge
A vacuum gauge reading of
22”Hg or higher is normal. A lower
reading indicates poor vacuum
where attention is required
Press on the manual
operation icon
Turn the vacuum on