Manual - Formech 450DT V1.0 - 0317
15
Use the + & - buttons to adjust the
standby level.
Press the back button to exit the
settings screen and return to the
operation screen.
The save button on the operation screen will also open the settings screen and will also bring the timer
value from the manual operation across to the settings screen.
The heater power and timer parameters may be edited before saving into memory. The timer button will
open an adjustment screen with a key-pad as described above. When complete, press the save button on the
settings screen to select a memory slot to save.
There are 20 memory locations.
Operating Procedure
This screen will open when the
settings button on the
operation screen is pressed. The
Manual mode default heater
settings are shown.
Heater power settings are adjusted
by pressing on the heater button
and changing the value using
the pop-up keypad on the adjust
screen.
450DT Settings
Once set to a required value, press on a zone and the value will transfer to that zone. Repeat the process on
the other zones to set the required heat power values.
Heat power may be set in 1% increments to achieve the required heat profi le.
The standby feature allows the Heater to idle at a lower heat power when in the rear position. The default
level is 50% and is adjustable in 5% increments.
Press on the standby button to adjust. The following screen will open:
Press on the value and the keypad
will appear. Enter the new value.
Press return.
Press the back arrow to return to
the settings screen.
The Heater Timer value is changed
in the same way.