
ForeRunner
ATM Switch Network Configuration Manual
A - 17
Confi
guring
SNMP
Configuring SNMP
2000
frf8PVCStatus
This trap indicates when an interworking PVC has
experienced an alarmed condition, either on the ATM
network side or Frame Relay side. It is also generated
when the PVC alarmed condition is cleared. It carries
the operational status of the PVC by the
frf8ConnOperStatus, as well as the reason why exiting,
entering, or changing the alarmed state
frf8ConnPVCAlarmReason.
If the interworking PVC changes its status by an
AdminStatus command (active/inactive/testing),
causing the frf8ConnOperStatus to change (up/down),
this trap is generated with frf8ConnPVCAlarmReason
set to no defect. This trap gives the support to manage
defects that might occur in either the Frame Relay net-
work or the ATM network, even if the PVC Opera-
tional Status is already down.
2001
ifLinkDown
This trap indicates that the SNMP agent has detected
that the ifOperStatus of this interface is about to transi-
tion into the down state.
2002
ifLinkUp
This trap indicates that the SNMP agent has detected
that the ifOperStatus of this interface has transitioned
out of the down state.
2003
framNakMsg
This trap is sent when a message from the SCP to the
FramePlus network module does not succeed. The
request that has failed is encoded within the trap as the
messageType
, and the reason for failure is encoded
within the
errorCode
. See Table A.3 for the message
types and the message requests. See Table A.4 for the
error codes and their meanings.
Table A.2 -
SNMP Traps Supported on the ForeRunner Switches (Continued)
Trap
Number
Trap Name
Description
Summary of Contents for forerunner series
Page 6: ......
Page 16: ...TOC 10 ForeRunner ATM Switch Network Configuration Manual Table of Contents ...
Page 20: ...LOF 4 ForeRunner ATM Switch Network Configuration Manual List of Figures ...
Page 22: ...LOT 2 ForeRunner ATM Switch Network Configuration Manual List of Tables ...
Page 30: ...viii ForeRunner ATM Switch Network Configuration Manual Preface ...
Page 144: ...3 58 ForeRunner ATM Switch Network Configuration Manual Configuring an Emulated LAN ...
Page 180: ...6 12 ForeRunner ATM Switch Network Configuration Manual ATM Forum PNNI ...
Page 220: ...9 6 ForeRunner ATM Switch Network Configuration Manual Configuring Timing ...
Page 300: ...D 24 ForeRunner ATM Switch Network Configuration Manual Configuring FramePlus Modules ...
Page 308: ...Acronyms 8 ForeRunner ATM Switch Network Configuration Manual Acronyms ...
Page 346: ...Glossary 38 ForeRunner ATM Switch Network Configuration Manual Glossary ...
Page 352: ...Index 6 ForeRunner ATM Switch Network Configuration Manual Index ...