The 

BALI RTFS

is a boiler with a

high performance heat-exchange
casing that works with gas burners
at atmospheric pressure. The follo-
wing models are available:

BALI RTFS E 18

with a thermal

power rating of 18 kW.

BALI RTFS E 24

with a thermal

power rating of 24 kW.

BALI RTFS E 32

with a thermal

power rating of 32 kW.

BALI RTFS E 36

with a thermal

power rating of 36.5 kW.

BALI 

boilers can be supplied in a 

PV

version, which means that they have
a circulation pump and an 8 lit.
expansion tank.

BALI

boilers meet the essential

requirements laid down in EEC
Directives for this product and Gas
Directive 93/396/EEC dated 29th
June 1990,  
Performance Directive 92/42/EEC
dated 21st May 1992.
EMC Directive 89/336/EEC dated
3rd May 1989, as amended by
Directive 92/31/EEC dated 28th April
1992,
European Community Low Voltage
Directive 73/23/EEC dated 19th
February 1973, as amended by
Directive 93/68/EEC dated 22nd July
1993, and is fitted with all the safety
devices called for in the current stan-
dards for this type of product.
The main technical characteristics of
the 

BALI 

boiler are listed below.

• High-performance cast iron heat
exchanger.
•  Insulation in glass wool with thick
aluminized paper (50 mm).
• Bodywork in electrically galvani-
sed steel plating, epoxy-polyester
powder coated.
•  Lit main switch.
• LED indications for: power on,
heating pump operating, burner ope-
rating, excess temperature cut-out,
burner cut-out.
• Heating  temperature  selector
(45/85°C).
•  Safety limit thermostat (110°C).
•  Smoke pressure switch
• Thermometer/Pressure Gauge
•  System drain stopcock.
•  Electrical system with printed elec-
tric circuit.

•  Provision for electrical connection
for a heating pump.
•  Provision for an electrical collec-
tion for a safety pressure switch to
guard against insufficient water.
•  Provision for connecting up a card
for managing a remote boiler (optio-
nal kit).
•  Provision for connecting up a cli-
matic unit (optional kit).
•  Provision for connecting up a card
for managing three heating areas
(optional kit).
• 8 lit expansion tank (for PV
models).
• Single-speed circulation unit (for
PV models).

2. TECHNICAL CHARACTERISTICS AND DIMENSIONS

2.1 Technical  Characteristics

6

Summary of Contents for BALI RTFS E 18

Page 1: ...BALI RTFS IST 03 C 080 01 INSTALLATION OPERATION AND MAINTENANCE CE 49BN3788 GB...

Page 2: ...1 Dear Customer Thank you for choosing and buying one of our boilers Please read these instructions carefully in order to install operate and maintain this equipment properly...

Page 3: ...o specific separated collection areas Keep the packing out of reach of chil dren as by its very nature it may constitute a source of danger Should the equipment break down and or function defectively...

Page 4: ...3 2 1 Packing pag 9 3 2 2 Choosing the installation position for the boiler pag 9 3 2 3 Installing the Boiler pag 9 3 2 4 Ventilation of Boiler Rooms pag 9 3 2 5 Smoke stack system pag 9 3 2 6 On site...

Page 5: ...tioning It must be reset manually Burner cut out LED Red 6 This light indicates that the burner safety device has tripped due to a malfunction Burner operation LED Yellow 7 This light indicates that t...

Page 6: ...fety thermo stat cut out has tripped and must be reset manually This is due to an operating fault and an authorised Service Centre or qualified person nel must be contacted for mainte nance 1 2 4 Cut...

Page 7: ...ed for in the current stan dards for this type of product The main technical characteristics of the BALI boiler are listed below High performance cast iron heat exchanger Insulation in glass wool with...

Page 8: ...GAS G 1 2 G 1 2 G 1 2 G 1 2 RETURN G 1 G 1 G 1 G 1 FEED G 1 G 1 G 1 G 1 Model RTFS E 18 RTFS E 24 RTFS E 32 RTFS E 36 L 510 510 610 610 2 2 Dimensions 7 fig 2...

Page 9: ...V Hz W A C Kg h N mm mm mbar Stm3 h mm C Kg h N mm mm mbar kg h EC Performance Class EC PIN Category Type Thermal Power Thermal Capacity Performance at nominal load Performance at reduced load 30 Main...

Page 10: ...ler to the system s feed and return pipes Remember that the plumbing system must include all the safety and control elements required in terms of current standards safety valve water pressure switch h...

Page 11: ...smoke flue pipe must be at least 250 mm and both terminals are to be positioned within a square with 500 mm sides The smoke flue is to comply with cur rent standards Air intake smoke flue double 80 mm...

Page 12: ...mp to prevent it being torn out This boiler must be connected to a 230V 50Hz electrical power supply When forming the connection respect the phase neutral polarity Installation standards must be com p...

Page 13: ...with a drain stopcock at the front of the unit that can be used to empty the system 3 4 Starting the Boiler 3 4 1 Preliminary Checks Before starting the boiler it is best to check that The smoke flue...

Page 14: ...R on the printed circuit VG Gas valve TM Contact Timer optional mar ked TIMER on the printed cir cuit PZ Ignition spark unit PA Water pressure switch optio nal marked with the pressure switch symbol o...

Page 15: ...that indicates the type of gas and pres sure for which the equipment is set 4 MAINTENANCE In order to ensure that the equip ment is efficient and that it functions correctly maintenance must be car ri...

Page 16: ...ocenigo 123 Tel 0365 878 31 Fax 0365 878361 e mail fondital fondital it export01 fondital it www fondital it Fondital reserves the right to make any changes it deems necessary without notice Fondital...

Reviews: