Manual # 26-0002901-00 / Revision H ScreenPro - High Resolution Seamless Switcher
50
Output Sync Adjust
Command: OSYNC n op <saveFlag>
Description:
Adjusts the Output Sync type for any of the three outputs.
Parameters:
n
- Output Sync: n[1-5], -C|+H+V|+H-V|-H+V|-H-V
op
- Output connector to make the change on: [B|H|P], where
B = BNC Output connector
H = Main HD15 Output connector
P = Preview HD15 Output connector
<saveFlag> - OPTIONAL PARAMETER
0 = Do NOT Save selected output sync to Flash memory
1 = Save selected output sync to Flash memory
(Default when this parameter is not specified.)
Example:
OSYNC 3 H: Adjusts the Output Sync value to be +H-V on the Main
HD15 connector.
Output Test Pattern Enable (See TPMODE command to Enable or Disable Test Patterns)
Command: OTPM m typ inv bx gr
Description:
Use to select Test Pattern options.
Parameters:
m
-
Overlay Mode: m[0-3],
OFF|ON (Main Only)|ON (Preview Only)|ON (Both Scalers)
This is the overlay mode for the Raster Box and Grid. The parameter is only applicable
when TPMODE is DISABLED. When TPMODE is ENABLED, the test pattern selected will
be shown on both Main and Preview. However, when TPMODE is enabled, you must still
place a number in this location when sending the command.
typ
-
Test Pattern Type: typ[0-4] V Gray Ramp|H Gray Scale|Burst|Color Bars|Black
inv
-
This is currently not used: Place a 0 in this location when sending the command.
bx
-
Test Pattern Raster Box: bx[0-1] OFF|ON
gr
-
Test Pattern Grid: gr[0|1] OFF|ON (Only applicable when TPMODE is ENABLED.)
Example:
TPMODE 1: Enables the Test Pattern Generator
OTPM 0 2 0 1 0: Burst Test Pattern is shown with the Raster Box ON.
TPMODE 0: Disables the Test Pattern Generator
OTPM 3 0 0 1 0: Enable the Raster Box on both Main and Preview.
OTPM? Returns: =[TPMode], [TYP], [M], [INV], [BX], [GR]