Input Clock Per Line Adjust
ICPL op sclr nnnn
Description:
Adjust the number of Input Clocks per Line.
Parameters:
op
- [A|D|M|I] Automatic | Debug | Manual | Increment
Note: Debug Mode is for Factory Use Only
sclr
- Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
nnnn
– Number of Clocks per Line [0 – 4096] when
op
=
M
Number to Increment by when
op
=
I
Example:
ICPL A P:
Automatically adjust the number of Input Clocks per
line
on
Preview.
ICPL M M 1364: Set Input Clocks per Line on Main to 1364.
ICPL I A 4:
Increment the number of Input Clocks per Line on
Scaler A by 4.
Input Configuration Recall
ICREC nn sclr n
Description:
Recalls a stored Input Configuration.
Parameters:
nn
-
Input Configuration Index; n[1 - 64]
sclr
- Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
n
-
Router input to which the input signal is connected.
Note: Router Input parameter only used on ScreenPro Plus.
Example:
(Assuming there is a saved Input Configuration in Index #1)
ICREC 1 M:
Loads the Input Configuration stored in Index #1 to the
source on Main.
ICREC 1 A 2:
Loads the Input Configuration stored in Index #1 on Scaler
A. In this example the input signal is sourced on router
input 2.
Input Configuration Reset
ICRST sclr
Description:
Resets the current input configuration of the scaler specified.
Parameters:
sclr
- Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
Example:
ICRST A: Reset the input configuration for Scaler A.