22
Commissioning
Fig. 4-10 Antenna cable
1
Antenna cable for identification
2
Antenna cable to automatic feeder
2. Route the supplied six meter antenna cable from the HygieneBox to the automatic feeder
and connect the cable using the plug connections.
Note:
Alternatively, you can connect the HygieneBox Basic to the automatic feeder using an
open cable tail. To do this, follow these steps:
1. Trim the six meter identification antenna cable to the correct length.
2. Strip the shortened antenna cable from the identification.
3. Disconnect the cable tail of the HygieneBox Basic to the identification from the HygieneBox
Basic circuit board.
4. Connect the removed cable tail of the HygieneBox Basic to the main board of the automatic
feeder.
5. Connect the HygieneBox Basic to the automatic feeder using the six meter antenna cable
supplied.
4.4
Install the ball valve externally
You install the ball valve as follows:
DANGER!
Fatal electric shock
The external ball valve is operated using a 220 V power supply. A uncovered external ball valve
can lead to a lethal electric shock.
►
Always install the external ball valve cover after removal.
1. Fasten the external ball valve to the back of the automatic feeder.
1
2