15. Drill a 15 mm diameter hole in the bottom of the automatic feeder.
Fig. 4-16 Drilling a hole for the flushing hose
1
Position the drill in the left corner
16. Route the flushing hose to the discharge pipe.
Fig. 4-17 Flushing hose fastened to discharge pipe
1
Discharge pipe
2
Flushing hose pushed onto discharge pipe
17. Push the flushing hose over the discharge pipe.
Note:
When using calibration scales, the flushing hose must not touch the mixer otherwise
this will falsify the measurements.
Fig. 4-18 External ball valve fitted with hoses
1
Flushing hose
2
Gully hose
18. Route the flushing hose through the hole drilled in the bottom of the automatic feeder.
1
1
2
1