HyperConverter User’s Manual 0006-5000-503
28
Turn the HyperConverter On.
Turn the Computer and Output Video Systems On. If everything is correctly installed, you will see
your computer's normal power up sequence appearing on both the Computer Display and the Video
Device (if the Video Device has a visible display).
2.7.3 Rackmount HyperConverter Installation for Sun Workstations
Turn the workstation off.
Select a convenient location for the HyperConverter.
Disconnect the Sun's High Resolution Monitor from the computer.
Connect the "IN" connectors of the Rackmount HyperConverter to the Sun with a 13W3 Male to 4
BNC Male Cable (Part # 0101-2000-100; not supplied unless specifically ordered). All 4 connectors of
this cable must be connected. Make sure that the Composite Sync connector of this cable is attached
to the H IN connector of the Rackmount HyperConverter.
Set the "SEP SYNC" switch on the Back Panel of the HyperConverter to the COMP SYNC position
(Down). Set the "SYNC ON GREEN" switch to the SYNC ON COMP position (Down).
Connect the television compatible device. Depending on your choice of type of output video, this will
require 1, 2, or 4 BNC cables for composite, S-Video or component respectively. If you require S-
Video output on a 4 pin DIN connector, use a 2 BNC Male to 4 pin DIN accessory cable (Part #
0108-2000-100; not supplied unless specifically ordered).
Plug the HyperConverter into AC power with an IEC-320 compatible power cable (American plug
configuration is part # 0020-2001-100; supplied with each unit). If you are outside North America,
you will have to supply an appropriate IEC-320 compatible power cord for the country that you are in.
If pass through of the Computer Graphics signal to a Computer Graphics Monitor is NOT required, set
the "75 OHM IN" switch to the 75 OHM IN position (Up). DO NOT USE the Unterminate switch
accessible from the front panel. Make sure that this switch is always in the "Terminate" (Up) position.
If pass through of the Computer Graphics signal to a Computer Graphics Monitor is required, set the
"75 OHM IN" switch to the 75 OHM OUT position (Down). DO NOT USE the Unterminate switch
accessible from the front panel. Make sure that this switch is always in the "Terminate" (Up) position.
Connect the Sun's monitor to the "OUT" BNC connectors of the Rackmount HyperConverter with a
13W3 Female to 4 BNC Male Cable (Part # 0102-2000-100; not supplied unless specifically ordered).
Make sure that the Composite Sync connector of this cable is attached to the H OUT connector of the
Rackmount HyperConverter.
Summary of Contents for HyperConverter 1024
Page 2: ...HyperConverter User s Manual 0006 5000 503 2...
Page 18: ...HyperConverter User s Manual 0006 5000 503 18...
Page 20: ...HyperConverter User s Manual 0006 5000 503 20 Figure 2 Cable Connection Diagram...
Page 33: ...HyperConverter User s Manual 0006 5000 503 33 Figure 3 Rackmount Version Backplate...
Page 43: ...HyperConverter User s Manual 0006 5000 503 43 Figure 5 Adjustments and Jumpers...