GAS SSUPPLY R
ROUTING ((continued)
The gas pipe must be suitably protected where it passes through fireplace openings. Any sleeving should be
sealed to the pipe at its ends.
This appliance is fitted with an inlet restictor elbow.
The open end of the supply pipe should be sealed temporarily during the installation of the firebox to prevent the
ingress of dirt and dust.
The appliance firefront is specially notched to allow the gas pipe to pass through when an over hearth supply is
necessary.
FITTING THE FIREBOX
The firebox may be fitted to the opening by using screw fixing or by the cable kit as described in the relevant
section. Leave the polythene coating in place until fitting procedures are complete to eliminate any risk of scratch-
ing the decorative finish.
To fit the firebox, firstly check the fire goes fully back into the opening. Secure the fire box by drilling and screw-
ing down the frame or base of the firebox, or use the cable fixing method.
INSTALLATION BBY C
CABLE FFIXING K
KIT
If this method is to be adopted then an extra 30mm fitting depth
should be allowed for Fitting depth for the firebox becomes a
recommended 240mm.
Drill the four holes for the rawl plugs, as shown in the diagram.
If the fireplace configuration does not allow the exact layout
given, the eyebolts should be positioned as close to the correct
layout as possible.
Before finally fitting cables, ensure the self adhesive sealing
strips are in position on the back of the appliance frame. The
fireframe must be sealed evenly to the fireplace opening all
around the periphery.
Thread the tensioning cables through the holes in the top of the fire-
box, then the eyelets, and finally through the lower holes in the back
of the firebox, as shown in the photographs.
Note: TThe bburner ttray M
MUST bbe rremoved aass pper rrelevant ssecction tto
ggain aaccccessss tto tthe ccable aadjussterss.
Push the appliance back into to fireplace, centralise, and pull the
loose tensioning cables through the holes into the firebox. Thread
the tensioner bolts onto the cables, with the nuts screwed down
close to the tensioner head.
Slide the screwed nipple onto the cable, pull cable tight, and tighten
nipple.
The tension of the cable may now be adjusted by using a suitable
spanner on the tensioner nuts to pull the appliance tightly against the
fireplace opening. Visually inspect the seal and reseat if necessary.
Note: D
DO NOT ccut ooff eexccessss ccable. Surplus cable must not be cut
off, as it will be impossible to refit the fire after servicing. Coil up the surplus cable,
and locate at rear of firebox.
Note :: IIf rrunningg aa cconccealed ggass ssupply, eenssure ggrommetss aare sseccure aaround
inccomingg ppipess.
77
11.0
11.1
A. 200mm
B. 350mm
C. 60mm
Dimension can
be +/-10mm
A
B
C
10.0