4-46
00-05/00-06= 4: Terminal UP / DOWN
The AC Drive accelerates with the UP command active and decelerates with the DOWN command active. Please
refer to parameter 03-00 – 03-05 for additional information.
Note:
To use this function both the UP and DOWN command have to be set to any of the input terminals.
00-05/00-06= 5: Communication Control
The frequency reference command is set via the RS-485 communication port.
Example:
Frequency Reference Command: 10.00Hz (AC Drive Node Address: 01)
Command String in Hexadecimal: 01 06 25 02 03 E8 23 B8
To set the frequency reference to 10.00, a value of “1000” (03E8h) has to be sent to the AC Drive.
Refer to parameter group 9 for additional information.
00-05/00-06= 6: Reserved
00-05/00-06= 7: Pulse Input
Frequency reference from an external pulse input. Can be used only with multi-function input terminal S3 (
03-02 = 25
or 26
). See parameter group 3 multi-function input selections 25 and 26.
S3
GND
0V
Serial pulse input
(Input resistance : 3.89 KΩ )
Specifications
Low Input Level
:
0.0 to 0.5 V
High Input Level
:
4.0 to 13.5 V
Duty cycle: (ON / OFF) 30 % to 70%
Pulse Input Frequency Range: 50 to 25 KHz
00-07
Main and Alternative Frequency Command Modes Default: 0
Range
【
0
】
: Main reference frequency
【
1
】
: Main fre alternative frequency
When set to 0, the reference frequency is set by the main reference frequency of parameter 00-05. When set to 1 the
reference frequency is sum of the main reference frequency (00-05) and alternative frequency (00-06).
Note:
The AC Drive will display the SE1 error when 00-07 = 1 and parameter 00-05 and 00-06 are set to the same
selection.
When parameter 00-06 is set to 0 (Keypad) the alternative frequency reference is set by parameter 05-01 (Frequency
setting of speed-stage 0).
00-08
Communication Frequency Command – READ ONLY Default: –
Range
【
0.00–599.00
】
: Hz
Display the frequency reference when 00-05 or 00-06 is set to communication control (3).
Example:
Pulse input frequency is 20Hz, frequency
upper limit is 50Hz (
00-12=50.00
), and
03-28=1
. AC Drive frequency is 20.00Hz.