Operating Manual EMGZ480
21
9.4
Description of Parameters EMGZ480 / 480.M16
Offset
Use:
This parameter stores the value determined by the CAN-Object 2051
Find offset
in [Digit].
Range:
–8000
to
8000
Default:
0
Increment:
1
Unit:
[Digit]
CAN Object:
2001h
Gain
Use:
This parameter stores the value determined with the CAN Object 2052
Calibration
. If the material tension cannot be simulated, you can also
enter a calculated value using the formulas in „8.2 Mathematical
Method (Module 1 only) “
Range:
0.100 to
32.000
Default:
1.000
Increment:
0.001
Unit:
[-]
CAN Object:
2002h
Force of sensor
Use:
This parameter stores the nominal force of the sensor. This value can be
found on the label of the force sensor.
Range:
1
to
9999
Default:
1000
Increment:
1
Unit:
[N, kN, cN]
CAN Object:
2003h
?
[lb, clb, klb]
Unit of sensor
Use:
This parameter stores the measuring unit of the sensor.
Range:
N, kN, cN
Default:
N
CAN Object:
2004h