Operating Manual EMGZ480
44
11.10
Object 2040: Parameter scaling analogue output
Scaling analogue output
Use:
This parameter determines which tension feedback value will
correspond to the maximum signal at the analogue output (10V
respectively 20mA).
Range:
A force value can be entered. The value has 4 digits. The decimal point
depends from the CAN-BUS Object 2003 “
Force of sensor”.
Default:
1000
Unit:
[N, kN, cN] or
[lb, klb, clb]
CAN Object:
2040h
Object description:
Index 2040
Name
Parameter Scaling analogue output
Object Code
ARRAY
Data Type
Integer 16
Category Mandatory
Input description:
Sub-Index 0
Description
Number of entries
Data type
Unsigned 8
Access ro
PDO Mapping
No
Value Range
1 .. 07h
Default Value
No
Sub-Index 1
Description Parameter
value
Data type
Integer 16
Access rw
PDO Mapping
No
Value Range
0 … 9999
Default Value
0
Sub-Index 2
Description Parameter
name
Data type
Visible String
Access ro
PDO Mapping
No
Value Range
String
Default Value
Scale analogue output