Operating Manual EMGZ480
59
15
CAN-BUS Catalogue Status Objects
15.1
Object 2100: Operating status
This object indicates the actual operating status.
Object description:
Index 2100
Name Operating
status
Object Code
ARRAY
Data Type
Integer 16
Category Mandatory
Input description:
Sub-Index 0
Description
Number of entries
Data type
Unsigned 8
Access ro
PDO Mapping
No
Value Range
01h
Default Value
No
Sub-Index 1
Description
Shows actual operating status
Data type
Integer 16
Access ro
PDO Mapping
PDO 1
Value Range
0 .. FFFF
Default Value
0
Bit 7: 0/1
⇒
Reserved
inactive/active
Bit 6: 0/1
⇒
Reserved
inactive/active
Bit 5: 0/1
⇒
Overload of analogue input
inactive/active
Bit 4: 0/1
⇒
Limit value 2
inactive/active
Bit 3: 0/1
⇒
Limit value 1
inactive/active
Bit 2: 0/1
⇒
Reserved for CMGZ 480
inactive/active
Bit 1: 0/1
⇒
Reserved for CMGZ 480
inactive/active
Bit 0: 0/1
⇒
Reserved for CMGZ 480
inactive/active
Analogue input: Shows whether the analogue input has a positive or negative overload
Limit value 2:
Shows whether the Limit value 2 activated
Limit value 1:
Shows whether the Limit value 1 activated