Operating Manual EMGZ480
60
15.2
Object 6150: Analogue Input Status
This object contains the status of the analogue input. Bit 1 and bit 2 cannot be set at the
same time.
MSB
LSB
Reserved
Negative overload
Positive overload
Error
7
3
2
1
0
Remarks:
Value Meaning
00h
No error at the analogue input
03h Positive
overload
05h Negative
overload
Object description:
Index 6150
Name
Analogue input status
Object Code
ARRAY
Data Type
Integer 16
Category Mandatory
Input description:
Sub-Index 0
Description
Number of entries
Data type
Unsigned 8
Access ro
PDO Mapping
no
Value Range
01h
Default Value
No
Sub-Index 1
Description
Analogue input status
Data type
Integer 16
Access ro
PDO Mapping
No
Value Range
0, 3, 5
Default Value
No