Operating Manual CMGZ 622
49
Output configuration
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
With this parameter, you can choose the output signal. With setting
„±10V“, the drive unit can run and brake both in forward and reverse
direction. With the other settings, the drive unit can only run and
brake in forward direction.
FMS recommends setting to „±10V“ if the used drive unit supports
this signal. However, for a brake the other settings are preferred.
Range:
±10V, 0...10V, 0...20mA, 4...20mA
Default:
±10V
Note:
The setting of this parameter must match with the jumper of the
analogue output (ref. to „19.2 Jumper for the analogue inputs /
outputs“).
Position of line drive
Applies to:
Line
drive
Use:
The output value of the controller depends on the line drive being
mounted before or after the force sensors (ref. to fig. 1). Depending
on the position, the polarity of the output value is different.
Range:
After sensor, Before sensor
Default:
After sensor
Ramp diameter
Applies to:
Unwind brake
Unwind drive
Winding drive
Use:
To optimize the controller against disturbances, the diameter should
not change too fast. For this, the diameter signal is led internally to a
ramp. Its rate of rise is defined using this parameter. The length of
the ramp defines the time the diameter will take for a change of
1mm.
Range:
0.1
to
60.0
Default:
1.0
Increment:
0.1
Unit:
[s]
Ramp reference
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
To optimize the controller against disturbances, the reference value
should not change too fast. For this, the reference value signal is led
internally to a ramp. Its rate of rise is defined using this parameter.
The length of the ramp defines the settling time the reference will
take to set to the new value.
Range:
0.1
to
20.0
Default:
1.0
Increment:
0.1
Unit:
[s]