Program
Program
Code Function
Code
Description
Entry
Code
20
Issue/Rev.
03
(8/97)
044
Additive Injector
Enter:
Four digit number indicating
044
#8 Plumbing
the products that this additive
injector is plumbed into.
1st digit - Product #1
2nd digit - Product #2
3rd digit - Product #3
4th digit - Product #4
A zero in the digit indicates
that the injector is not plumbed
into that product, a one indicates
that the injector is plumbed
into that product. (e.g., 1110
indicates that the injector is
plumbed into products 1, 2,and 3.)
__ __ __ __
Note: If that additive injector output is configured for use and this entry is "0000" the indication is that it is plumbed into the loading arm downstream
of the metering system.
045-089
Unassigned at Present
045-089
090
Input/Output
Enter:
"1" One Product
090
Configuration
"2" Two Products
"3" Three Products
"4" Four Products
__
Warning: If you have already programmed codes 001 through 045, do not program this code. It may change what
you have already programmed.
Note: Entering the above number will program the AccuLoad II to a typical Input and Output configuration for the number of products selected.
Refer to manual MN06066L for input and output assignments when using this method of configuring the AccuLoad II-RBU.
091
Enter:
Press "ENTER". The output configuration
091
Configuration
will be displayed. Press "ENTER". The
input configuration will be displayed.
Press "ENTER" again to print the
configuration
report.
092-099
Unassigned at Present
092-099