Program
Code
Function
Code Description
Prod 1
Prod 2
Prod 3
Prod 4
Issue/Rev. 0.3 (8/97)
63
546
Middle Product Vapor
Enter:
Four digits in Degrees
Pressure (P2)
C or Degrees F that corresponds
Temperature
to the middle vapor pressure
in code 545.
First digit "0" = Plus Degrees
First digit "1" = Minus Degrees
(e.g., 0030 = +030). Temperature units are
dependent on entry made in code 441
of the Systems Directory
_____
_____
_____
_____
547
High Vapor
Enter:
Four digits indicating
Pressure (P3)
the high vapor pressure in PSIA, Bars
or
kg/cm
2
in tenths of pressure
units, (e.g., 100.0)
Pressure units are dependent
on entry made in code 541
of the Systems Directory.
____._ ____._ ____._ ____._
Note: This entry must not exceed the entry made in 545 or it will be ignored.
548
High Product Vapor
Enter:
Four digits in Degrees
Pressure (P3)
C or Degrees F that corresponds
Temperature
to the high vapor pressure
in code 546.
First digit "0" = Plus Degrees
First digit "1" = Minus Degrees
(e.g., 0600 = +060). Temperature units are
dependent on entry made in
code 441 of the Systems
Directory
_____ _____ _____ _____
549
Maintenance Pressure Enter:
Four digit maintenance
pressure to be used when a pressure
transducer is not installed,
in tenths of units (e.g., 150.0)
Pressure units dependent on
selection made in code 541
of the Systems Directory.
"0000" disables this feature.
____.__ ____.__ ____.__ ____.__
550-599
Unassigned at Present