![FMC Technologies AccuLoad II Programming Workbook Download Page 28](http://html.mh-extra.com/html/fmc-technologies/accuload-ii/accuload-ii_programming-workbook_2312619028.webp)
Program
Program
Code Function
Code
Description
Entry
Code
Issue/Rev. 0.3 (8/97)
23
105
Product 4 Alarm Check/Reset
Read only, Press E to clear
None
105
Available Alarms
BH: Blend High
LF: Low Flow
BL: Blend Low
LP: Low Pressure
BP: Back Pressure
LT: Low Temperature
CF: Not Configured Flow
OA: Overrun
DA: Program Code
PR: Pressure Transducer
DR: Density Transducer
PS: Pulse Security
HD: High Density
PT: Pulse Transmission Alarm
HF: Excess High Flow
TP: Temperature Probe
HP: High Pressure
UF: Unauthorized Flow
HT: High Temperature
VF: Valve Fault
LD: Low Density
ZF: Zero Flow
106
Recipe Alarms Check/Reset
Read only, Press E to clear
None
106
Available
Alarms
DA: Program Code
107
Transaction Alarms
To be read only
None
107
108
Ready Mode Alarms
To be read only
None
108
109
Set Time
Enter:
Five digits. Two digits
109
for hours, Two digits for minutes
and one to indicate military,
time, AM or PM. The last digit will
be "0" = AM, "1" = PM and
"2" = Military (e.g., 01:130)
__ __ __ __ __
110
Set Date
Enter:
Six digits. Two digits for
110
month followed by two digits for
day, followed by digits for
year (e.g., 011288)
__ __ __ __ __ __
111
Dynamic Display
Enter:
Two digits in seconds
111
Time-out
of time-out (e.g., 15)
"00" Display will remain till
the "CLEAR" key is pressed
"99" will disable the dynamic displays.
__ __