Program
Program
Code Function
Code
Description
Entry
Code
40
Issue/Rev.
03
(8/97)
754
EIA-485 Printer
Enter: "0" No 485 Security
754
Security
"1"
XON/XOFF
"2" DEC Protocol
"3" PTB - FX Protocol
"4" PTB - LQ Protocol
__
Note: Options 3 and 4 of this code apply to RBU-02 and above firmware.
755
Shared Printer
Enter: "0" No Security Alarm
755
Security Alarm
"1" Local Security Alarm
"2" Prg Security Alarm
__
Note: Used with DEC Security.
756
Select Volumes to
Enter: Five digit number indicating
756
the totals that will be printed
on the Product Receipt Ticket.
1st digit - Raw Totals
2nd digit - Gross Totals
3rd digit - Gross at Standard
Temperature Totals
4th digit - Net Totals
5th digit - Mass Totals
A zero in the digit indicates
the total will not be printed,
a one indicates the total
will be printed. (e.g., 01100
indicates that Gross totals
and the Gross at Standard
Temperature will be printed
on the Product Receipt Ticket.)
__ __ __ __ __
Note: The current load ticket can have all five of the volumes printed on it. However, any reprint of that load ticket will only contain the totals that
have been selected for local storage in code 307 and in this program code.