Program
Code
Function
Code Description
Prod 1
Prod 2
Prod 3
Prod 4
Issue/Rev. 0.3 (8/97)
57
346
Meter Factor #3
Enter:
Five digits as one whole
number followed by four
decimals (e.g., 1.0048)
_._____ _._____ _._____ _._____
347
Flow Rate for
Enter:
Four digits in whole units
Meter Factor #4
per minute (e.g., 0080)
_____
_____
_____
_____
Note: If flow rate is set at zero the AccuLoad II will ignore code 348.
348
Meter Factor #4
Enter:
Five digits as one whole
number followed by four
decimals (e.g., 1.0058)
_._____ _._____ _._____ _._____
349
Meter Factor %
Enter:
Five digits representing
Change/Deg.
the meter factor percent
change per degree of unit
temperature in percentage,
(e.g.,
0.0012)
_._____ _._____ _._____ _._____
350
Meter Factor
Enter:
Four digits representing
Reference
the temperature that the percent
Temperature
meter factor variation was determined,
Three whole units and one
decimal in degrees (e.g., 120.1)
_____._ _____._ _____._ _____._
351
Pulse Output
Enter:
"0" Raw Pulse Out 1
"1" Gross Pulse Out 1
"2" Gst Pulse Out 1
"3" Net Pulse Out 1
"4" Mass Pulse Out 1
__
__
__
__
352
Pulse Resolution
Enter:
Six digits defining
Output
the printer output resolution
(units/pulse) in thousandths of units,
"000000" Disables this feature
(e.g., 010.0)
__
__
__ .
__
Note: Input pulses must be 2.5 times greater than the output pulses (e.g., 100 output pulses/unit volume requires at least 250 input pulses/unit
volume.
353
Input Resolution
Enter:
Four digit number representing
the number of pulses per unit of
registration (e.g., 0100)
Entry must be between 0025
and 9999.
_______ _______ _______ _______