Basic Operation
Basic
Operation
Open the door. If you need to raise the top plate to accommodate the container to
be mixed, turn on the POWER switch and push the UP button. Wait a few seconds
until the UP light goes out. This will raise the top plate about two inches. Repeat if
necessary.
To quickly stop the machine, push the EMERGENCY
STOP button. If you open the door during the operation,
the paint mixer will stop.
Note
1.
After opening the front door, place the container(s) near the center of the
table. The diagram below illustrates the proper gallon can placement.
Cans must be removed from cardboard case before mixing.
2 Gallon Cans
Lead Screw Centerline
3 Gallon Cans
Lead Screw Centerline
4 Gallon Cans
Lead Screw Centerline
Figure 3. Gallon Can Placement
16 | Harbil 5G Mixer
Fluid Management Customer Service 1.800.462.2466