![Fluid Management HARBIL 5G End User Manual Download Page 38](http://html1.mh-extra.com/html/fluid-management/harbil-5g/harbil-5g_end-user-manual_2308809038.webp)
Removing Circuit Board
Read all of the following instructions. If you have any doubt about performing these
procedures, please contact Customer Service at Fluid Management.
Turn to the Parts Section for component identification and location.
Removing
Circuit Board
WARNING
ELECTRICAL HAZARD
The mixer must be unplugged before attempting this
procedure. There is a chance of electrical shock.
Removing Circuit Board Procedure
1.
Unplug the electrical cord.
2.
Remove the sheet metal screws on the control panel and slowly swing it
down.
3.
Remove the push-on type connector at the bottom of the printed circuit
board.
Pull the connector with alternating left and right force away from the circuit
board. It is not necessary to loosen the screws on the connector.
4.
Remove the 4 nuts from the screws that attach the circuit board to the
control panel.
5.
Install the new board with the push-on connector.
6.
Reinstall the control panel and the top cover.
7.
Connect the electrical cord.
Fluid Management Customer Service 1.800.462.2466