Opening the Mixer
Remove Exterior Panels
1.
Using a medium-size screwdriver or 1/4” nut driver, remove the sheet metal
screws securing the top cover. Lift it off the mixer.
Opening the
Mixer
Figure 5. Removing the Mixer Covers
2.
In the same manner, take off the upper rear panel and left and right upper
side panels covering the sides and back, and set to the side of the work
area.
3.
If your machine has a 4-sided skirt, remove it now.
4.
At the back of the mixer, squeeze the power supply strain relief with a pair of
pliers, and pull it off the cord. Move the back panel away from the machine
(the cord will still be attached).
5.
Remove the right and left side panels, and the lower front panel.
6.
To prevent damage, remove the mixer door by lifting the door off its pins.
7.
Cut the upper wire tie wrap securing the 3 cables to the outer frame at the
left side of the machine.
8.
Remove the remaining front sheet metal covering. Carefully prop the front
piece (two front columns with control box assembly) to the side of the
machine, being careful to not damage the cords.
Fluid Management Customer Service 1.800.462.2466