Troubleshooting
PROBLEM
CHECK
ACTION
The DC motor runs, but the top plate
does not move.
for loose set screw in one of the
DC motor couplings.
key and set screw on timing
gears.
• Tighten set screw(s).
• Tighten key and set screw.
The mixer stops before completing
shake cycle.
for broken or loose wire in the DC
motor cabling.
• Replace DC motor cable.
The mixer speeds up and slows
down. The START light is blinking.
if front door is making contact with
the safety switch in the control box.
broken wire in DC motor cabling.
• Adjust safety switch.
• Replace DC motor cable.
The mixer crushes or throws cans.
clamping force may be out of
adjustment.
• Adjust clamping force as required