01
Http: // www.flowmeter.cc
1. Operation Principle
<>The operation of a magnetic flowmeter or mag meter is based upon Faraday's Law, which
states that the voltage induced across any conductor as it moves at right angles through a
magnetic field is proportional to the velocity of that conductor.
Faraday's Formula:
E is proportional to V x B x D where:
E = The voltage generated in a conductor
V = The velocity of the conductor
B = The magnetic field strength
D = The length of the conductor
To apply this principle to flow measurement with a magnetic flowmeter, it is necessary first to state
that the fluid being measured must be electrically conductive for the Faraday principle to apply. As
applied to the design of magnetic flowmeters, Faraday's Law indicates that signal voltage (E) is
dependent on the average liquid velocity (V) the magnetic field strength (B) and the length of the
conductor (D) (which in this instance is the distance between the electrodes).In the case of
wafer-style magnetic flowmeters, a magnetic field is established throughout the entire
cross-section of the flow tube (Figure 1). If this magnetic field is considered as the measuring
element of the magnetic flowmeter, it can be seen that the measuring element is exposed to the
hydraulic conditions throughout the entire cross-section of the flowmeter. With insertion-style
flowmeters, the magnetic field radiates outward from the inserted probe (Figure 2).
2. Main Features and Applications
Electromagnetic flowmeter consists of two parts of the sensor and transmitter. KF700-type
electromagnetic flowmeter for measuring a variety of acid, alkali, salt solution, paper pulp, slurry
and other conductive liquid or liquid-solid two-phase medium volume flow. In the chemical, alloy,
water supply and drainage, sewage treatment, food, sugar, paper making, environmental protection
and other departments to be widely application.
Following characteristics of sensor:
(1) The whole welded structure,good sealing performance;
functional diagram
SENSORS PARTS
SENSORS